Megger DLRO200-115 Digital Low Resistance Ohmmeter
Resistances ranging from 0.1μΩ to 1Ω, test currents from 10 amps up to 200 amps.
- DLRO200-115
- By Megger
Overview
Features
- Test currents from 10 A to 200 A d.c.
- Filtered direct current output eliminates magnetic transients
- 0.1 µΩ best resolution
- Small and weighs less than 32 lbs (14.5kg)
- On board memory for up to 300 test results and notes
- RS232 port to download stored results or for real time output to a printer
- Manual, auto, and continuous test modes
- Operating temp: 14 to +122°F (-10 to +50°C)
- Accuracy:
- Voltage; ±0.5% ± 0.1 mV
- Current; ±0.5% ± 0.1 A
- Resistance; Better than 1% from 100 μΩ to 100 mΩ
- Note: test leads NOT included
What's in the Box
- 16ft test leads with clips
- 2 potential probes
Description
The Megger DLRO200-115 Digital Low Resistance Ohmmeter is designed to check and measure contact resistance in high voltage circuit breakers, disconnecting switches (isolators), busbar joints, or for any low resistance measurement. The test set accurately measure resistances ranging from 0.1μΩ to 1Ω, at high currents.
This versatile instrument can provide test currents from 10 amps up to 200 amps, subject to the load resistance and supply voltage. For those applications that demand a smooth dc current, the DLRO200-115 has extra filtering on the output to reduce mains frequency ripple and can drive 200 amps through a total current loop resistance of 11 milliohms. The filtered output of the DLRO200-115 also eliminates magnetic transients that could inductively trip a breaker's control (bus differential relay), if left in the test circuit.
The unique design allows the weight and size of the DLRO200- 115 to be kept to a minimum; the instrument weighs less than 32lbs. (14.5 kg). This small size plus a water/dust ingress rating of IP54 makes the test set equally at home in the workshop, on the production floor or in the field.
As many as 300 sets of results may be stored in the test set's on-board memory for later download to a PC or may be sent directly to a printer via the RS232 port. You may also add notes to any stored result by using the on-board alphanumeric keypad, thereby making later identification of results easier to determine.
As well as adding notes to stored results, the alphanumeric keypad allows you to set the test current directly by keying in the value required. The DLRO200-115 will check the continuity of the test circuit, and will quickly ramp the test current up to the desired level. The keyboard is also used to set upper and lower limits for the result and to prevent the use of excessive currents by setting an upper limit to the allowable test current.
The DLRO200-115 uses a four terminal measurement technique to cancel the resistance of the test leads from the measurement.
The test set operates in one of three modes, which are simply selected from the on-screen menu.
CONTINUOUS mode is provided for users who wish to monitor a resistance over a period of time. Connect the test leads, select the test current and press the TEST button. The DLRO200-115 will pass a current continuously, and measure the load resistance at 2 second intervals, until the test button is pressed to stop the test or the test circuit is interrupted.
In NORMAL mode you connect the leads, select the test current and press the TEST button. The test current will ramp up to the desired level, hold for 2 seconds and then ramp down. The whole process takes approximately 10 seconds.
In AUTO mode select the desired current, connect the current leads and press the TEST button. The TEST lamp will flash to show that the DLRO200-115 is ready to carry out a test. As soon as the potential leads are connected, a test will start. To repeat a test, simply break contact with the voltage probes and remake contact.
Documents
Accessories
Test Leads
Accessories
Please consider these optional accessories.
Need Help? Call a Temperature engineer at 1-800-884-4967