AW-Lake JV-UF Positive Displacement Flow Meter
Low viscosity fluids (solvents, scale inhibitor, methanol, DEF) in stainless steel bodies (303 and 316SS).
- By AW-Lake
-
Manufacturer has some models in stock. View available part numbers.
Overview
Features
- 0.0005 to 20 gpm flow ranges
- Accuracy:
- ±1.5% over full range
- ±2.5% over full range
- Up to 6,000 psi max. operating temperature
- Up to 500:1 turn down ratio
- 7-point logarithmic calibration
- Stainless steel (DIN 1.4122) gears and bearings
- FKM, FFKM, or PTFE o-rings
Description
The AW-Lake JV-UF positive displacement flow meter is designed for low viscosity fluids (solvents, scale inhibitor, methanol, DEF) in Stainless Steel bodies (303 and 316SS). We reduced the clearances around the gears to prevent fluid from slipping past and now measure flows as low as 0.0005 gpm with a 5cP fluid (we can measure fluids below 1.0 cP) and as high as 20 gpm. The JV-UF meters pair with our existing sensors to provide you with the data you need. Common applications include:
- Chemical, methanol, and fuel injection & dosing systems
- Test stands
- Hydraulic positioning systems
- Coolant & lubrication monitoring
Documents
In Stock
Manufacturer Stock
Part Number | Price | Available | |
---|---|---|---|
JVS-12UFE-N-S |
$3,648.00 | 1 in stock |
Interested in Other Part Numbers?
Other part numbers are available to order but are not currently in stock. Current availability for non-stock parts is "Usually ships in 2-3 weeks. Call for expedite options". Click here to select options
Need Help? Call a Flow engineer at 1-800-884-4967
We're open 8:00 am to 5:00 pm ET