Fuji Electric VG Series FKP Gauge Pressure Transmitter
Direct mount measurement for pressures up to 1,450 psi, SIL 2/3 safety features, <80 ms response time, with universal HART or proprietary and faster Fuji communications protocol.
Overview
Features
- Range 1 to 1,450 psi (81 mbar to 100 bar)
- SIL levels 2 and 3
- <80 ms response time
- ±0.1% of span accuracy
- ±0.2% of upper range limit stability for 10 years
- Process temperature
- -40 to 212°F (-40 to 100°C) for silicone filling oil
- -4 to 176°F (-20 to 80°C) for fluorinated filling oil
- Fuji and HART communication protocols
- Hazardous area approvals
- IP66/IP67 and NEMA 4X
- Analog or 5-digit local display
Description
The Fuji Electric VG Series FKP gauge pressure transmitter uses a unique micro-capacitive silicon sensor and state-of-the-art digital signal processing to provide exceptional accuracy and stability. The transmitter's silicon sensor assures this accuracy for all of the suppressed calibration ranges without additional adjustment. The FKP offers a sampling period of 40 ms and a response time of 80 ms.
The FKP transmitter incorporates specific hardware and software features to comply with Safety Integrity Levels (SIL) 2 and 3 according to IEC 61508 and 61511 standards. The transmitters have a safety failure rate of 97%.
The FKP transmitter's advanced floating cell technology protects against temperature variations and overpressure, and substantially reduces the overall measurement error. The burnout current value can be adjusted within the ranges of 3.2 to 4 and 20 to 22.5 mA in conformance with NAMUR NE43 recommendations. The transmitter's output signal can be linearized using up to 14 points.
The electronics unit, local indicators and electronics housing are interchangeable among all VG series transmitters. The VG series transmitters can also communicate using either the universal HART protocol or the proprietary, faster Fuji Electric communication protocol. Various options are available to address a wide range of process industry applications, including a full range of hazardous area approvals, a built-in RFI filter and lightning arrester, analog or 5-digit local display with engineering units, stainless steel electronics housing, and a wide selection of wetted part materials.
Documents
Spec Sheets
Manuals
- Fuji Electric VG Series FKP Gauge Pressure Transmitter Manual PDF (8.1 MB)
- Fuji Electric VG Series FKP Gauge Pressure Transmitter Safety Manual PDF (1.6 MB)
Other
- Fuji Electric VG Series FKP Gauge Pressure Transmitter Certificate of Compliance PDF (681 KB)
- Fuji Electric VG Series FKP Gauge Pressure Transmitter SIL Certificate PDF (367 KB)
Links
Need Help? Call a Calibration engineer at 1-800-884-4967
We're open 8:00 am to 5:30 pm ET