Fuji Electric V6 Series FKD Differential Pressure Transmitter for Remote Seal
Measures differential pressure up to 2,900 psi, for use with diaphragm seal, communicates using HART communications protocol.
Overview
Features
- Range 1 to 2,900 psi gauge (3.2 to 200,000 mbar)
- Up to ±0.065% of calibrated span accuracy
- 40ms response time
- ±0.2% of upper range limit stability
- 0.05% of calibrated span linearity
- Process temperature
- -40 to 302°F (-40 to 150°C) for rigid mounting
- 32 to 662°F (0 to 350°C) for capillary design and high temperature filling fluid
- HART 7 communication protocol
- Safety Integrity Level 2 or 3 according to IEC 61508 and IEC 61511 standards
- Hazardous area approvals
- Optional LCD display with 3 magnetic push buttons for contactless configuration
- IP66/IP67 and NEMA 4X
- 5-digit local display
Description
The Fuji Electric V6 Series FKD differential pressure transmitter for remote seal uses a unique micro-capacitive silicon sensor and state-of-the-art digital signal processing to provide exceptional accuracy and stability. The transmitter's silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. Using a silicon measurement diaphragm limits hysteresis and mechanical fatigue problems on the sensitive element, and provides the user with very high zero stability and long-term reliability.
The FKD V6 transmitter's advanced floating cell technology protects against temperature variations and overpressure, and substantially reduces the overall measurement error. The burnout current value can be adjusted in the ranges of 3.4 to 3.8 and 20.8 to 22.5 mA, and can be compliant with NAMUR NE43 recommendations. The transmitter's output signal can be linearized using up to 14 points.
The electronics unit, local indicators and electronics housing are interchangeable among all FCX-AIV V6 transmitters. Various options are available to address a wide range of process industry applications, including a full range of hazardous area approvals, a built-in RFI filter and lightning arrester, 5-digit local display with engineering units, stainless steel electronics housing, and a wide selection of wetted part materials. An optional local configurator with three magnetic switches allows the user to configure the transmitter without opening the indicator cover.
Documents
Spec Sheets
Manuals
Other
Links
Need Help? Call a Temperature engineer at 1-800-884-4967
We're open 8:00 am to 5:30 pm ET