Bacharach PCA2 Combustion Analyzer
Commercial grade, handheld combustion and emissions analyzer for sampling of combustion equipment.
Overview
Features
- Ambient air temperature
- Range: -4° to 999°F
- Accuracy: up to ±2°F
- Stack temperature
- Range: -4° to 2192°F
- Accuracy: up to ±4°F
- Oxygen
- Range: 0 to 20.9%
- Accuracy: ±0.3%
- Carbon monoxide
- Range: 0 to 4,000 ppm (H2 comp); 4,001 to 20,000 ppm (high range)
- Accuracy: up to ±5% or ±10 ppm
- Nitric oxide
- Range: 0 to 3,000 ppm
- Accuracy: up to ±5% or ±5 ppm
- Nitrogen dioxide
- Range: 0 to 500 ppm
- Accuracy: up to ±5% or ±5 ppm
- Sulfur dioxide
- Range:0 to 5,000 ppm
- Accuracy: up to ±5% or ±10 ppm
- Pressure/draft
- Range: -72 to +72 inwc
- Accuracy: up to ±2% or 0.02 inwc
- Combustion efficiency range: 0.1 to 100%
- Excess air range: 1.0 to 250%
- NOx range: 0 to 3,500 ppm
- Carbon dioxide range: 0 to fuel dependent maximum
- Calculated ranges: NOx referenced to % O2, CO referenced to % O2, NO referenced to % O2, NO2 referenced to % O2, SO2 referenced to % O2,
- Memory holds 500 complete logged combustion test records
- Selectable fuels: natural gas, oil ( #2, #4, #6), propane, coal, wood, kerosene, bagasse and digester gas
Description
The Bacharach PCA®2 is a commercial grade, handheld combustion and emissions analyzer for sampling of light industrial, institutional, commercial and residential furnaces, boilers and appliances. The Bacharach PCA®2 is the perfect tool for service technicians and boiler contractors who need to ensure safe operating conditions, determine combustion efficiency, or perform emissions testing in combustion applications.
The Bacharach PCA®2 directly measures and displays:
- Flue gas oxygen (O2)
- Carbon monoxide (CO)
- Stack temperature
- Draft
- Differential pressure
- Combustion air temperature
Additional Bacharach PCA®2 Combustion Analyzer models are available which also measure and display:
- Nitric oxide (NO)
- Nitrogen dioxide (NO2)
- Sulfur dioxide (SO2)
Simultaneously, the Bacharach PCA®2 calculates and displays combustion efficiency (EFF), excess air (EA), carbon dioxide (CO2), NOx and oxygen reference values. The Bacharach PCA®2 performs combustion calculations for ten fuels including natural gas, oil (#2, #4, #6)propane, coal, wood, kerosene, bagasse and digester gas. The Bacharach PCA®2 has a large backlit graphic display which shows eight different measurements and calculated values simultaneously. An internal memory logs up to 500 test records.
The Bacharach PCA®2 combustion analyzer ships complete with meter, IRDA printer, hard carry case, probe and hose assembly, factory calibrated sensors, protective boot, USB cable, software and manual.
Documents
Accessories
Calibration
Sensors/Probes
Accessories
Please consider these optional accessories.
Need Help? Call a Temperature engineer at 1-800-884-4967
We're open 8:00 am to 5:30 pm ET