Amprobe ACD-15 TRMS PRO Clamp-on Multimeter
Digital multimeter measuring AC/DC voltage up to 600 V, AC current up to 2000 A with True RMS capabilities.
Overview
Features
- True RMS
- Backlight
- AC/DC voltage up to 600 V
- AC current up to 2000 A
- Resistance
- Frequency
- Capacitance
- Non-contact voltage level detection
- Audible continuity
- Auto-check automatically selects DC V, AC V or Resistance (Ω)
- Auto and manual ranging
- Auto power off
- Automatic polarity
- Low battery indication
- Data hold
- Large LCD display
- Accommodates conductors up to 45 mm (1.77")
- Voltage overload protection for all functions up to 600 V AC/DC
Description
The Amprobe ACD-15 TRMS PRO 2000 A clamp-on multimeter has a wide range of measuring features built into one professional meter. It measures AC/DC voltage up to 600 V, AC current up to 2000 A, resistance, frequency and capacitance. True RMS measurement ensures accurate readings in electrically noisy environments. The Amprobe ACD-15 TRMS PRO has non-contact votage level detection and audible continuity check. The auto-check feature automatically selects DCV, ACV or resistance (Ω).
Amprobe ACD-15 TRMS PRO 2000 A clamp-on multimeters feature auto and manual ranging, auto power off function, automatic polarity detection, low battery indication and a data hold function. The Amprobe ACD-15 TRMS PRO has a 3-5/6 digit 6000 count LCD display. The jaws accommodate conductors up to 45 mm (1.77") in diameter and the multimeter has voltage overload protection for all functions up to 600 V AC/DC.
The Amprobe ACD-15 TRMS PRO 2000 A Clamp-on Multimeter ships complete with:
- Test leads
- Carrying case
- Manual
Amprobe ACD-15 TRMS PRO 2000 A Clamp-on Multimeter Specifications
Feature | Range | Accuracy |
---|---|---|
DC Voltage | ||
6.000 V | 0.5% + 3d | |
60.00 V | 1.0% + 5d | |
600.0 V | 2.0% + 5d | |
NMRR: | >30 dB @ 50/60 Hz | |
CMRR: | >100 dB @ Dc, 50/60 Hz, Rs=1kΩ | |
Hi-Z DCV Input Impedance: | 5 MΩ, 90 pF nominal | |
AutoCheck Lo-Z DCV input impedance: | Initially 1.6 kΩ, 90 pF nominal; impedance increases significantly as display voltage increases from 50 V (typical). Typical impedances vs display voltages for reference are 15 kΩ @ 100 V; 100 kΩ @ 300 V; 210 kΩ @ 600 V | |
AutoCheck DCV Threshold: | > +1.5 V DC or < -1.0 V DC nominal | |
AC Voltage | ||
50 Hz/60 Hz | 6.000 V, 60.00 V | 1.5% + 5d |
600.0 V | 2.0% + 5d | |
50 Hz ~ 500 Hz | 6.000 V, 60.00 V | 2.0% + 5d |
600.0 V | 2.5% + 5d | |
CMRR: | >60 dB @ Dc to 60 Hz, Rs=1kΩ | |
Hi-Z ACV Input Impedance: | 5 MΩ, 90 pF nominal | |
AutoCheck Lo-Z ACV input impedance: | Initially 1.6 kΩ, 90 pF nominal; impedance increases significantly as display voltage increases from 50 V (typical). Typical impedances vs display voltages for reference are 5 kΩ @ 100 V; 100 kΩ @ 300 V; 210 kΩ @ 600 V | |
AutoCheck ACV Threshold: | > 2 VAC (50/60 Hz) nominal. True RMS model ACD-15 RRMS-PRO Crest less than 1.6:1 at full scale & less than 3.3:1 at half scale | |
Resistance | ||
6.000 kΩ 2 | 1.2% + 6d1, 3 | |
60.00 kΩ, 600.0 kΩ | 1.0% + 4d | |
6.000 MΩ | 2.0% + 4d | |
Open circuit voltage: 0.4 VDC typical | 1Cool down interval 2 minutes after over 50 V measurements
in Auto-VΩ position 2Beeper on while reading < 0.025 kΩ 3Add 40d to specified accuracy while reading is |
|
600Ω with Continuity Beeper | ||
600.0 Ω | 2.0% + 8d1 | |
Continuity beeper response: | < 100 µs | |
Open circuit voltage: | 0.4 VDC typical | |
Audible threshold : | Between 10 Ω and 300 Ω 1) Add 40d to specified accuracy while reading is below 20% of range | |
Frequency | ||
Range: 10 Hz ~ 30 kHz 0 Hz ~ 1 kHz 10 Hz ~ 1 kHz |
Sensitivity (Sine RMS) 4 V 30 V 60 V |
Voltage Range: 6.000 V 60.00 V 600.0 V |
Accuracy | 0.5% + 4d | |
Max display: | 9999 counts | |
Diode Tester | ||
Open circuit voltage | Test current | |
less than 1.6 V DC | 0.4 mA (typical) | |
Audible threshold: | between 0.15 V & 0.080 V | |
Capacitance | ||
100.0 nF2, 1000 nF | 3.5% + 5d1, 3 | |
10.00 µF, 100.0 µF, 2000 µF | ||
1) Accuracies with film capacitor or better | ||
2) Accuracy below 50 nF is not specified | ||
3) Specified with battery voltage above 2.8 V (app. half-full battery). Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4 V | ||
Non-contact EF-detection | ||
Typical voltage | Bar graph indication | |
15 V to 85 V | - | |
40 V to 130 V | -- | |
60 V to 210 V | --- | |
90 V to 300 V | ---- | |
Above 120 V | ---- | |
Indication: | Bar graph segments & audible beep tones proportional to the field strength | |
Detection frequency: | 50/60 Hz | |
Detection antenna: | Top side of the stationary jaw | |
Probe-contact EF-detection: | For more precise indication of live wires, use the red (+) probe for direct contact measurements | |
AC current (clamp-on) | ||
50 Hz/60 Hz | 400.0 A, 2000 A | 1.5% + 5d |
1) Add 8d to specified accuracy while reading is below 10% of range | ||
2) Induced error from adjacent current-carrying conductor: < 0.06 A/A | ||
3) Specified accuracy is for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position errors introduced are: Add 1% to specified accuracy for measurements made within jaw marking lines (away from jaw opening) Add 4% to specified accuracy for measurements made beyond jaw marking lines (toward jaws opening) |
Need Help? Call a Temperature engineer at 1-800-884-4967