Testo 6321 Differential Pressure Transmitter
Differential pressure transmitter with full functionality for automated air conditioning and ventilation applications.
Overview
Features
- Differential pressure measurement form 100 Pa to 2 bar
- Magnetic valve for automatic zero-point adjustment
- Accuracy: ±1.2% of range + intrinsic error of 0.3pa
- P2A software for parameter adjustment/analysis
- Free scalability within the measuring range
- Variety of analog outputs and measuring ranges
- Optional display
Description
The Testo 6321 differential pressure transmitter provides excellent performance at an affordable price for automated air conditioning and ventilation applications. Because automated building processes necessitate precision monitoring, heavy demands are placed on the monitoring equipment. The Testo 6321 differential pressure transmitter fulfills these requirements by ensuring excellent system functionality. When climate conditions are optimized by highly accurate measurement systems and creating long-term differential pressure stability, the result is energy savings.
Like all Testo transmitters, the Testo 6321 differential pressure transmitter features P2A software. The analysis tools incorporated in the software test analog and relay signals and display min/max values. The transmitter software also includes an operational hour counter which means reports are stored with a time/date stamp to provide a history of error events.
Applications for the Testo 6321 Differential Pressure Transmitter
- Industrial & commercial buildings
- Offices buildings
- Exhibition halls
- Museums & libraries
- School buildings & hotels
Testo 6321 Differential Pressure Transmitter Specifications
Differential Pressure Parameters | ||
---|---|---|
Measuring Range | 0 to 100 Pa 0 to 10 hPa 0 to 50 hPa 0 to 100 hPa 0 to 500 hPa 0 to 20 hPa 0 to 50 hPa 0 to 100 hPa 0 to 500 hPa 0 to 1000 hPa 0 to 2000 hPa |
-100 to 100 Pa -10 to 10 hPa -20 to 20 hPa -50 to 50 hPa -100 to 100 hPa -500 to 500 hPa -1000 to 1000 hPa -2000 to 2000 hPa |
Measurement Uncertainty | ±1.2% of measurement range final value ±0.3 Pa. Temperature gain drift: 0.05% of
measuring range per Kelvin deviation from nominal temperature 22°C Zero-point drift: 0% (due to zero-point adjustment. |
|
Sensor | Piezoresistive sensor | |
Auto. zero-point adjustment | via magnetic valve | |
Overload capacity | Measuring Range: 0 to 100 Pa 0 to 10 hPa 0 to 20 hPa 0 to 50 hPa 0 to 100 hPa 0 to 500 hPa 0 to 1000 hPa 0 to 2000 hPa -100 to 100 Pa -10 to 10 hPa -20 to 20 hPa -50 to 50 hPa -100 to 100 hPa -500 to 500 hPa -1000 to 1000 hPa -2000 to 2000 hPa |
Overload: 20000 Pa 200 hPa 200 hPa 750 hPa 750 hPa 2500 hPa 2500 hPa 2500 hPa 20000 Pa 200 hPa 200 hPa 750 hPa 750 hPa 2500 hPa 2500 hPa 2500 hPa |
Analog Outputs | ||
Output type |
0 to 1/5/10 V (4-wire) 4 to 20 mA (4-wire) |
|
Measuring rate | 1/s | |
Resolution | 12 bit | |
Accuracy of the analog outputs |
0 to 1 V: ±2.5 mV 0 to 5 V: ±12.5 mV 0 to 10 V: ±25 mV 4 to 20 mA: ±0.05 mA |
|
Max load | 500 Ω | |
Further Outputs | ||
Other analog outptus | Min in DIN for P2A software (adjustment and parameterization software) | |
Supply | ||
Voltage supply | 20 to 30 V AC/DC | |
Current consumption | 30 mA |