E+H Proline Prosonic Flow P 500 Clamp-On Ultrasonic Flow Meter
For limited spaces in process industries with up to 3 I/Os; available in set of 1 or 2.
Overview
Features
- Only 2 x DN inlet and outlet runs required when using 2 sensor sets and FlowDC
- 0 to 50ft/s (0 to 15m/s) measuring range
- 1/2 to 160in nominal diameter range
- Medium temperature range:
- DN 15 to 65 (1/2 to 2 1/2in): -40 to 302°F (-40 to 150°C)
- DN 50 to 4000 (2 to 160in): -40 to 338°F (-40 to 170°C)
- Maximum measurement error, volume flow:
- ±3% o.r. for DN 15
- ±2% o.r. for DN 25 to DN 200
- ±2% o.r. above DN 200
- Mounting without process interruption
- Backlit display with touch control and WLAN access
- Standard cable between sensor and transmitter
- SIL by design
Description
The E+H Proline Prosonic Flow P 500 Clamp-On Ultrasonic Flow Meter applies a non-invasive measuring principle independent of pressure, density, and conductivity. The meter provides a bidirectional measurement of various fluids, e.g. liquid hydrocarbons and chemicals. The built-in FlowDC (Flow Disturbance Compensation) maintains accuracy even when the meter is mounted with a short inlet run. A stable signal is accomplished via maintenance-free permanent mounting from outside with coupling pads. Sensors for GRP and plastic pipes are available. The freely combinable I/Os offer full access to process and diagnostic information, as well as variety and reduced complexity.
The measuring system uses a measurement method based on the transit time difference. In this measurement method, acoustic signals (ultrasonic) are transmitted between two sensors. Signal transmission is bidirectional, i.e. the sensor operates as both a sound transmitter and a sound receiver.
As the speed of propagation of the sound waves is slower against the flow direction than in the flow direction, this results in a transit time difference. This transit time difference is directly proportional to the flow velocity.
The measuring system calculates the volume flow of the medium from the measured transit time difference and the pipe cross-sectional area. The sound velocity of the medium is simultaneously measured along with the transit time difference. With this additional measured variable, it is possible to differentiate between different media or monitor the medium quality.
Documents
Applications
This product can be used in the following applications:
- Boiler Feedwater
- Clean Water
- Coolant
- Corrosives
- DI/RO Water
- Energy Auditing
- Explosive or Hazardous Areas
- Hydraulics Flow
- Intrinsically Safe
- Oil, Gas and Petrochemical
- Paper
- Power Generation
- Preventative Maintenance
- Refrigeration Control / Monitoring
- Semiconductor
- Utilities
- Waste-water and Grey Water
Need Help? Call a Flow engineer at 1-800-884-4967
We're open 8:00 am to 5:30 pm ET